Draft California 2020 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 6 - Lahontan Region

Water Body Name: Markleeville Town Ditch
Water Body ID: CAR6321006020171227037638
Water Body Type: River & Stream
 
DECISION ID
102645
Region 6     
Markleeville Town Ditch
 
Pollutant: Indicator Bacteria
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Four lines of evidence, two which assess the available E. coli data for the REC-1 beneficial use and two which assess the available fecal coliform data for the MUN beneficial use, are available in the administrative record to assess this pollutant. 0 of 3 E. coli geometric mean samples exceed the water quality objective for the REC-1 beneficial use; 0 of 5 E. coli Statistical Threshold Value (STV) samples exceed the objective; 3 of 7 fecal coliform log-mean samples exceed the objective for the MUN beneficial use; 1 of 5 fecal coliform STV samples exceed the water quality objective.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used does not satisfy the data quantity requirements of section 6.1.5 of the Policy.
3. 0 of 3 E. coli geometric mean samples exceed the water quality objective for the REC-1 beneficial use; 0 of 5 E. coli Statistical Threshold Value (STV) samples exceed the objective; 3 of 7 fecal coliform log-mean samples exceed the objective for the MUN beneficial use; 1 of 5 fecal coliform STV samples exceed the water quality objective. These sample sizes are insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples per beneficial use/fraction assessed are needed to determine if a beneficial use is fully supported using table 3.2.
4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 102645, Indicator Bacteria
Region 6     
Markleeville Town Ditch
 
LOE ID: 99779
 
Pollutant: Escherichia coli (E. coli)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 5
Number of Exceedances: 0
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed RWB6_BACT_Monitoring data for Markleeville Town Ditch to determine beneficial use support and the results are as follows: 0 of the 5 samples exceeded the Statistical Threshold Value (STV) water quality standard for E. coli. The STV is based on a 10% exceedance rate that is calculated monthly.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for Regional Water Board 6 Bacteria Monitoring.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The bacteria water quality objective applicable to all waters, except Lake Tahoe, where the salinity is less than 10 parts per thousand (ppth) 95 percent or more of the time is a STATISTICAL THRESHOLD VALUE (STV) of 320 cfu/100 mL not to be exceeded more than 10 percent of the time (calculated monthly).
Objective/Criterion Reference: Inland Surface Waters, Enclosed Bays, and Estuaries Plan. Part 1: Trash Provisions; Part 2: Tribal Subsistence Beneficial Uses and Mercury Provisions; Part 3: Bacteria Provisions and Variance Policy
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s), station(s): 632DTCB01
Temporal Representation: The samples were collected between the days of 2014-04-29 and 2014-08-15 .
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 102645, Indicator Bacteria
Region 6     
Markleeville Town Ditch
 
LOE ID: 129263
 
Pollutant: Fecal Coliform
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 7
Number of Exceedances: 3
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed RWB6_BACT_Monitoring data for Markleeville Town Ditch to determine beneficial use support and the results are as follows: 3 of the 7 samples exceeded the logmean water quality standard for Coliform, Fecal. This is a 30-day rolling logmean that is calculated daily.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for Regional Water Board 6 Bacteria Monitoring.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain concentrations of coliform organisms attributable to anthropogenic sources, including human and livestock wastes. The fecal coliform concentration during any 30-day period shall not exceed a log mean of 20/100 ml. (Lahontan Region Basin Plan)
Objective/Criterion Reference: Water Quality Control Plan for the Lahontan Region (as amended)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s), station(s): 632DTCB01
Temporal Representation: The samples were collected between the days of 2014-04-29 and 2014-08-15 .
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 102645, Indicator Bacteria
Region 6     
Markleeville Town Ditch
 
LOE ID: 99918
 
Pollutant: Escherichia coli (E. coli)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 3
Number of Exceedances: 0
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed RWB6_BACT_Monitoring data for Markleeville Town Ditch to determine beneficial use support and the results are as follows: 0 of the 3 samples exceeded the geomean water quality standard for E. coli. This is a six week rolling geomean that is calculated weekly.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for Regional Water Board 6 Bacteria Monitoring.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The bacteria water quality objective applicable to all waters, except Lake Tahoe, where the salinity is less than 10 parts per thousand (ppth) 95 percent or more of the time is a six-week rolling GEOMETRIC MEAN (GM) of Escherichia coli (E. coli) not to exceed 100 colony forming units per 100 milliliters (cfu/100 mL) (calculated weekly).
Objective/Criterion Reference: Inland Surface Waters, Enclosed Bays, and Estuaries Plan. Part 1: Trash Provisions; Part 2: Tribal Subsistence Beneficial Uses and Mercury Provisions; Part 3: Bacteria Provisions and Variance Policy
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s), station(s): 632DTCB01
Temporal Representation: The samples were collected between the days of 2014-04-29 and 2014-08-15 .
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 102645, Indicator Bacteria
Region 6     
Markleeville Town Ditch
 
LOE ID: 129278
 
Pollutant: Fecal Coliform
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 5
Number of Exceedances: 1
 
Data and Information Type: PATHOGEN MONITORING
Data Used to Assess Water Quality: Water Board staff assessed RWB6_BACT_Monitoring data for Markleeville Town Ditch to determine beneficial use support and the results are as follows: 1 of the 5 samples exceeded the water quality standard for Coliform, Fecal. The water quality standard is based on a 10% exceedance rate that is calculated monthly.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for Regional Water Board 6 Bacteria Monitoring.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain concentrations of coliform organisms attributable to anthropogenic sources, including human and livestock wastes. The fecal coliform concentration during any 30-day period shall not exceed a log mean of 20/100 ml, nor shall more than 10 percent of all samples collected during any 30-day period exceed 40/100 ml. (Lahontan Region Basin Plan)
Objective/Criterion Reference: Water Quality Control Plan for the Lahontan Region (as amended)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s), station(s): 632DTCB01
Temporal Representation: The samples were collected between the days of 2014-04-29 and 2014-08-15 .
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program