Burton Creek
 
Pollutant: Alkalinity as CaCO3
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. 0 of 1 samples exceed the guideline for alkalinity.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. 0 of 1 samples exceeded the guideline and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 100994, Alkalinity as CaCO3
Region 6     
Burton Creek
 
LOE ID: 98477
 
Pollutant: Alkalinity as CaCO3
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Burton Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Alkalinity as CaCO3.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The National Recommended Water Quality Criteria for Alkalinity as CaCO3 for the protection of freshwater aquatic life is not less than 20000 ug/L. (National Recommended Water Quality Criteria 2016)
Objective/Criterion Reference: National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Current as of 08/03/2016.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s) (634S16291)
Temporal Representation: The samples were collected between the dates of 2016-06-14 and 2016-06-14
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
100995
Region 6     
Burton Creek
 
Pollutant: Oxygen, Dissolved
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. One of one samples exceed the objective for dissolved oxygen saturation and zero of one samples exceed the objective for dissolved oxygen concentration.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. One of one samples exceed the objective for dissolved oxygen saturation and zero of one samples exceed the objective for dissolved oxygen concentration and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 100995, Oxygen, Dissolved
Region 6     
Burton Creek
 
LOE ID: 130140
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Burton Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Oxygen, Dissolved.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: For waters with the beneficial uses of COLD, COLD with SPWN, WARM, and WARM with SPWN, the minimum dissolved oxygen concentration shall not be less than that specified in Table 3-6. (Water Quality Control Plan, Lahontan Region)
Objective/Criterion Reference: Water Quality Control Plan for the Lahontan Region (as amended)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s) (634S16291)
Temporal Representation: The samples were collected between the dates of 2016-06-14 and 2016-06-14
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
Line of Evidence (LOE) for Decision ID 100995, Oxygen, Dissolved
Region 6     
Burton Creek
 
LOE ID: 130137
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Burton Creek to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality standard for Oxygen, Saturation.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The Water Quality Control Plan for the Lahontan Region's water quality objective states that the dissolved oxygen concentration shall not be less than 80 percent of saturation.
Objective/Criterion Reference: Water Quality Control Plan for the Lahontan Region (as amended)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site(s) (634S16291)
Temporal Representation: The samples were collected between the dates of 2016-06-14 and 2016-06-14
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program
 
 
DECISION ID
100996
Region 6     
Burton Creek
 
Pollutant: Specific Conductivity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. 0 of 1 samples exceed the guideline for specific conductivity.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. 0 of 1 samples exceeded the guideline and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 100996, Specific Conductivity
Region 6     
Burton Creek
 
LOE ID: 98625
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed TRPA Tahoe Ambient Monitoring data for Burton Creek to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for SpecificConductivity.
Data Reference: Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for the Tahoe Regional Planning Agency (TRPA) Tahoe Ambient Monitoring program.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: Water designated as MUN shall not contain concentrations of chemical constituents in excess of the maximum contaminant level (MCL) or secondary maximum contaminant level (SMCL) based upon drinking water standards specified in Title 22 of the California Code of Regulations (Water Quality Control Plan, Lahontan Region).
Objective/Criterion Reference: Water Quality Control Plan for the Lahontan Region (as amended)
 
Evaluation Guideline: California Maximum Contaminant Levels (MCLs) apply to ambient waters under the Lahontan Basin Plan's \Chemical Constituents\" objective. The California Secondary MCL for specific conductivity is 900 uS/cm."
Guideline Reference: California Code of Regulations, Title 22, Division 4, Chapter 15. Domestic Water Quality and Monitoring
 
Spatial Representation: The samples were collected at 1 monitoring site(s) (634S16291)
Temporal Representation: The samples were collected between the dates of 2016-06-14 and 2016-06-14
Environmental Conditions:
QAPP Information: Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program