Issue Date: November 22, 1995
Revision Date: March 10, 2000
FCI Environmental, Inc.
Analog Hydrocarbon Probe AHP-100, Digital Hydrocarbon Probe DHP-100
Out-Of-Tank Product Detector (Vapor-Phase)
Detector
Output Type | Quantitative |
---|---|
Sampling Frequency | Continuous |
Operating Principle | Fiber optic |
Test Results (for tests conducted with 1000 ppm test gas):
Unleaded Gasoline | Synthetic Gasoline | Xylene | Benzene | 2-methylbutane | |
---|---|---|---|---|---|
AHP-100 | |||||
Relative accuracy* (%) | 12 | 22 | 2 | 35 | N/R |
Bias (%) | -7 | -2 | 1 | -23 | N/R |
Precision (%) | 4 | 15 | 1 | 11 | N/R |
Detection time (min) | < 1 | < 1 | < 1 | < 1 | N/R |
Fall time (min) | < 1 | < 1 | < 1 | < 1 | N/R |
Lower detection limit (ppm) | 137 | 220 | 84 | 519 | N/R |
DHP-100 | |||||
Relative accuracy* (%) | 18 | 29 | 0 | 17 | N/R |
Bias (%) | 1 | -12 | 0 | 17 | N/R |
Precision (%) | 9 | 10 | 0 | 11 | N/R |
Detection time (min) | < 1 | < 1 | < 1 | < 1 | N/R |
Fall time (min) | < 1 | < 1 | < 1 | < 1 | N/R |
Lower detection limit (ppm) | 73 | 118 | 45 | 280 | N/R |
Specificity Results (%) (corrected for sensitivity differences)
AHP | DHP-100 | |
---|---|---|
Unleaded gasoline | 93 | 101 |
Synthetic gasoline** | 100 | 92 |
Synthetic gasoline*** | 98 | 88 |
JP-4 jet fuel | 105 | 109 |
Benzene | 76 | 89 |
Trimethylbenzene | 107 | 104 |
P-xylene | 101 | 100 |
Xylene | 103 | N/R |
Toluene | 96 | 97 |
Pentane | N/R | N/R |
Methane | N/R | N/R |
Butane | N/R | N/R |
2-methylbutane | N/R | N/R |
N-hexane | N/R | 108 |
** EPA March 1990 protocol
*** Radian June 1990 protocol
Comments
1000 ppm tests used a certified blend of concentrated gas to simulate a leak. 10 ppm test used a measured quantity of liquid product to simulate a leak.
- FCI Environmental, Inc.
1181 Grier Dr., Bldg. B
Las Vegas, NV 89119
Tel: (800) 510-3627 - Evaluator: Ken Wilcox Associates
Tel: (816) 443-2494
Date of Evaluation: 03/07/94, 12/05/94
Home | Vendors: A–F | Vendors: G–M | Vendors: N–S | Vendors: T–Z | Method Index
Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. For full details, please refer to our expanded DISCLAIMER page.